{"title":"Electric Boiler Panels","description":null,"products":[{"product_id":"electric-boiler-radiant-heating-panel-with-pex-manifold","title":"Electric Boiler Radiant Heating Panel with PEX Manifold","description":"\u003cstyle\u003e\n  .ws-electric-panel {\n    --ws-red: #ad002c;\n    --ws-red-dark: #9e0929;\n    --ws-heading: #17243a;\n    --ws-text: #3f4145;\n    --ws-card-gray: #f8f8f8;\n    --ws-pink: #f8edef;\n    --ws-border: #d9d9d9;\n    --ws-white: #ffffff;\n\n    width: 100%;\n    max-width: 1200px;\n    margin: 0 auto;\n    color: var(--ws-text);\n    font-family: Montserrat, Arial, sans-serif;\n    font-size: 17px;\n    font-weight: 400;\n    line-height: 1.65;\n  }\n\n  .ws-electric-panel,\n  .ws-electric-panel * {\n    box-sizing: border-box;\n  }\n\n  .ws-electric-panel h2,\n  .ws-electric-panel h3,\n  .ws-electric-panel h4 {\n    margin-top: 0;\n    color: var(--ws-heading);\n    font-family: Montserrat, Arial, sans-serif;\n    line-height: 1.25;\n  }\n\n  .ws-electric-panel h2 {\n    margin-bottom: 18px;\n    font-size: 32px;\n    font-weight: 700;\n  }\n\n  .ws-electric-panel h3 {\n    margin-bottom: 28px;\n    font-size: 28px;\n    font-weight: 700;\n    text-transform: uppercase;\n  }\n\n  .ws-electric-panel h4 {\n    margin-bottom: 8px;\n    font-size: 18px;\n    font-weight: 700;\n  }\n\n  .ws-electric-panel p {\n    margin-top: 0;\n    margin-bottom: 17px;\n    font-size: 17px;\n    line-height: 1.65;\n  }\n\n  .ws-electric-panel-section {\n    margin: 54px 0;\n  }\n\n  \/* INTRODUCTION *\/\n\n  .ws-electric-panel-intro {\n    margin-top: 30px;\n    padding: 0;\n    border: 0;\n    border-radius: 0;\n    background: transparent;\n  }\n\n  .ws-electric-panel-intro-copy {\n    max-width: 1080px;\n  }\n\n  .ws-electric-panel-lead {\n    color: var(--ws-heading);\n    font-size: 18px !important;\n    font-weight: 500;\n    line-height: 1.65;\n  }\n\n  \/* TOP STATISTIC CARDS *\/\n\n  .ws-electric-panel-metrics {\n    display: grid;\n    grid-template-columns: repeat(3, minmax(0, 1fr));\n    gap: 14px;\n    margin: 30px 0 31px;\n  }\n\n  .ws-electric-panel-metric {\n    display: flex;\n    min-height: 104px;\n    padding: 20px 16px;\n    flex-direction: column;\n    align-items: center;\n    justify-content: center;\n    border: 1px solid var(--ws-border);\n    border-radius: 12px;\n    background: var(--ws-card-gray);\n    text-align: center;\n  }\n\n  .ws-electric-panel-metric strong {\n    display: block;\n    margin: 0 0 5px;\n    color: var(--ws-red);\n    font-size: 26px;\n    font-weight: 700;\n    letter-spacing: -0.3px;\n    line-height: 1.2;\n  }\n\n  .ws-electric-panel-metric span {\n    display: block;\n    color: var(--ws-heading);\n    font-size: 17px;\n    font-weight: 400;\n    letter-spacing: 0;\n    line-height: 1.4;\n    text-transform: none;\n  }\n\n  \/* PRODUCT CALLOUT *\/\n\n  .ws-electric-panel-callout {\n    margin: 0;\n    padding: 19px 22px;\n    border: 0;\n    border-left: 5px solid #b30b38;\n    border-radius: 8px;\n    background: var(--ws-pink);\n    color: var(--ws-heading);\n    font-size: 16px;\n    line-height: 1.65;\n  }\n\n  .ws-electric-panel-callout p {\n    margin: 0;\n    color: var(--ws-heading);\n    font-size: 16px;\n    line-height: 1.65;\n  }\n\n  .ws-electric-panel-callout strong {\n    color: var(--ws-red-dark);\n    font-weight: 700;\n  }\n\n  \/* KEY FEATURES *\/\n\n  .ws-electric-panel-feature-list {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    column-gap: 70px;\n    row-gap: 28px;\n    margin: 0;\n    padding: 0;\n    list-style: none;\n  }\n\n  .ws-electric-panel-feature-list li {\n    display: flex;\n    margin: 0;\n    align-items: flex-start;\n    gap: 14px;\n    color: var(--ws-text);\n    font-size: 16px;\n    font-weight: 400;\n    line-height: 1.55;\n  }\n\n  .ws-electric-panel-feature-list li::before {\n    content: \"✓\";\n    display: inline-flex;\n    flex: 0 0 29px;\n    width: 29px;\n    height: 29px;\n    margin-top: 1px;\n    align-items: center;\n    justify-content: center;\n    border-radius: 50%;\n    background: var(--ws-red);\n    color: var(--ws-white);\n    font-size: 18px;\n    font-weight: 700;\n    line-height: 1;\n  }\n\n  \/* RADIANT HEATING CONTENT *\/\n\n  .ws-electric-panel-radiant {\n    max-width: 1080px;\n  }\n\n  .ws-electric-panel-radiant p {\n    font-size: 17px;\n    line-height: 1.65;\n  }\n\n  \/* TECHNICAL SPECIFICATIONS *\/\n\n  .ws-electric-panel-specs {\n    display: grid;\n    grid-template-columns: repeat(2, minmax(0, 1fr));\n    gap: 20px;\n    width: 100%;\n    align-items: start;\n  }\n\n  .ws-electric-panel-spec-table {\n  width: 100%;\n  height: fit-content;\n  align-self: start;\n  border-top: 1px solid var(--ws-border);\n  border-left: 1px solid var(--ws-border);\n  background: var(--ws-white);\n  }\n\n  .ws-electric-panel-spec-row {\n    display: grid;\n    grid-template-columns: 43% 57%;\n    min-height: 54px;\n  }\n\n  .ws-electric-panel-spec-label,\n  .ws-electric-panel-spec-value {\n    display: flex;\n    padding: 14px 15px;\n    align-items: flex-start;\n    border-right: 1px solid var(--ws-border);\n    border-bottom: 1px solid var(--ws-border);\n    font-family: Montserrat, Arial, sans-serif;\n    font-size: 16px;\n    line-height: 1.6;\n  }\n\n  .ws-electric-panel-spec-label {\n    background: #f3f3f3;\n    color: #111111;\n    font-weight: 700;\n  }\n\n  .ws-electric-panel-spec-value {\n    background: var(--ws-white);\n    color: var(--ws-heading);\n    font-weight: 400;\n  }\n\n  \/* INSTALLATION NOTICE *\/\n\n  .ws-electric-panel-notice {\n    padding: 25px 28px;\n    border-left: 5px solid var(--ws-red);\n    border-radius: 8px;\n    background: var(--ws-pink);\n    color: var(--ws-heading);\n    font-size: 16px;\n    line-height: 1.65;\n  }\n\n  .ws-electric-panel-notice h3 {\n    margin-bottom: 12px;\n    color: var(--ws-red-dark);\n    font-size: 21px;\n    font-weight: 700;\n    text-transform: none;\n  }\n\n  .ws-electric-panel-notice p {\n    color: var(--ws-heading);\n    font-size: 16px;\n    line-height: 1.65;\n  }\n\n  .ws-electric-panel-notice p:last-child {\n    margin-bottom: 0;\n  }\n\n  \/* TABLET *\/\n\n  @media screen and (max-width: 850px) {\n    .ws-electric-panel-feature-list {\n      column-gap: 35px;\n    }\n\n    .ws-electric-panel-feature-list li {\n      font-size: 18px;\n    }\n  }\n\n  \/* MOBILE *\/\n\n  @media screen and (max-width: 750px) {\n    .ws-electric-panel {\n      font-size: 16px;\n    }\n\n    .ws-electric-panel h2 {\n      font-size: 28px;\n    }\n\n    .ws-electric-panel h3 {\n      margin-bottom: 23px;\n      font-size: 24px;\n    }\n\n    .ws-electric-panel p,\n    .ws-electric-panel-radiant p {\n      font-size: 16px;\n    }\n\n    .ws-electric-panel-section {\n      margin: 40px 0;\n    }\n\n    .ws-electric-panel-metrics,\n    .ws-electric-panel-feature-list,\n    .ws-electric-panel-specs {\n      grid-template-columns: 1fr;\n    }\n\n    .ws-electric-panel-metrics {\n      gap: 12px;\n    }\n\n    .ws-electric-panel-metric {\n      min-height: 92px;\n    }\n\n    .ws-electric-panel-feature-list {\n      row-gap: 22px;\n    }\n\n    .ws-electric-panel-feature-list li {\n      font-size: 16px;\n    }\n\n    .ws-electric-panel-specs {\n      gap: 18px;\n    }\n\n    .ws-electric-panel-callout,\n    .ws-electric-panel-notice {\n      padding: 18px;\n    }\n  }\n\n  @media screen and (max-width: 480px) {\n    .ws-electric-panel-spec-row {\n      grid-template-columns: 42% 58%;\n    }\n\n    .ws-electric-panel-spec-label,\n    .ws-electric-panel-spec-value {\n      padding: 12px 11px;\n      font-size: 14px;\n    }\n  }\n\n  @media screen and (max-width: 380px) {\n    .ws-electric-panel-spec-row {\n      grid-template-columns: 1fr;\n    }\n\n    .ws-electric-panel-spec-label {\n      padding-bottom: 7px;\n    }\n\n    .ws-electric-panel-spec-value {\n      padding-top: 7px;\n    }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"ws-electric-panel\"\u003e\n\n  \u003c!-- INTRODUCTION --\u003e\n\n  \u003csection class=\"ws-electric-panel-intro\"\u003e\n    \u003cdiv class=\"ws-electric-panel-intro-copy\"\u003e\n\n      \u003ch2\u003eComplete Electric Boiler Radiant Heating Panel\u003c\/h2\u003e\n\n      \u003cp class=\"ws-electric-panel-lead\"\u003e\n        Simplify your hydronic radiant heating installation with a\n        professionally assembled electric boiler system organized on one\n        ready-to-install panel.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        This complete system combines the electric boiler, circulator pump,\n        expansion tank, air-management components, system controls and\n        stainless steel PEX manifold in one organized mechanical assembly.\n        The preassembled design helps reduce field piping and component\n        assembly while creating a clean, professional installation.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        Choose a 2, 3, 4, 5 or 6-loop manifold configuration based on the\n        number of PEX heating circuits required for your radiant floor\n        heating project.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- STATISTIC CARDS --\u003e\n\n    \u003cdiv class=\"ws-electric-panel-metrics\"\u003e\n\n      \u003cdiv class=\"ws-electric-panel-metric\"\u003e\n        \u003cstrong\u003eONE PANEL\u003c\/strong\u003e\n        \u003cspan\u003eComplete System Layout\u003c\/span\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"ws-electric-panel-metric\"\u003e\n        \u003cstrong\u003e2–6 LOOPS\u003c\/strong\u003e\n        \u003cspan\u003ePEX Manifold Options\u003c\/span\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"ws-electric-panel-metric\"\u003e\n        \u003cstrong\u003ePREASSEMBLED\u003c\/strong\u003e\n        \u003cspan\u003eReduced Field Assembly\u003c\/span\u003e\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- PRODUCT CALLOUT --\u003e\n\n    \u003cdiv class=\"ws-electric-panel-callout\"\u003e\n      \u003cp\u003e\n        \u003cstrong\u003eComplete radiant heating panel:\u003c\/strong\u003e\n        The electric boiler, circulator, expansion tank, system controls and\n        PEX manifold are professionally arranged on one mounting panel.\n        Final electrical, thermostat, system-water and PEX connections are\n        completed at the installation location.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- KEY FEATURES --\u003e\n\n  \u003csection class=\"ws-electric-panel-section\"\u003e\n\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n\n    \u003cul class=\"ws-electric-panel-feature-list\"\u003e\n\n      \u003cli\u003e\n        Complete electric boiler radiant heating system assembled on one panel\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Professionally organized layout creates a clean mechanical installation\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Integrated electric boiler provides the hydronic system heat source\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Dedicated circulator pump moves water through the radiant heating loops\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Expansion tank accommodates changes in system-water volume\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Integrated air-management components help remove trapped system air\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Stainless steel PEX supply and return manifold\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Individual manifold controls support loop adjustment and balancing\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Available with 2, 3, 4, 5 or 6-loop manifold configurations\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Integrated valves and gauges support system monitoring and servicing\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Compact layout keeps major system components in one central location\n      \u003c\/li\u003e\n\n      \u003cli\u003e\n        Professionally assembled and supported in the USA\n      \u003c\/li\u003e\n\n    \u003c\/ul\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- DESIGNED FOR RADIANT FLOOR HEATING --\u003e\n\n  \u003csection class=\"ws-electric-panel-section ws-electric-panel-radiant\"\u003e\n\n    \u003ch3\u003eDesigned for Radiant Floor Heating\u003c\/h3\u003e\n\n    \u003cp\u003e\n      This electric boiler panel is designed to serve as the heat source,\n      circulation system and distribution point for a closed-loop hydronic\n      radiant floor heating system.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Heated water moves from the electric boiler through the circulator and\n      stainless steel manifold. The manifold distributes the heated water\n      through the connected PEX circuits before it returns to the panel to be\n      reheated.\n    \u003c\/p\u003e\n\n    \u003cp\u003e\n      Individual manifold controls allow the flow through each radiant loop\n      to be adjusted and balanced as part of a properly designed system. The\n      organized panel format keeps the primary mechanical components\n      accessible for installation, operation and future service.\n    \u003c\/p\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\n  \u003csection class=\"ws-electric-panel-section\"\u003e\n\n    \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n    \u003cdiv class=\"ws-electric-panel-specs\"\u003e\n\n      \u003c!-- LEFT TABLE --\u003e\n\n      \u003cdiv class=\"ws-electric-panel-spec-table\"\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Product Type\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Preassembled electric boiler radiant heating panel\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Application\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Closed-loop hydronic radiant floor heating\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Heat Source\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Integrated electric boiler\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Manifold Options\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            2, 3, 4, 5 or 6 loops\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Manifold Material\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Stainless steel\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Loop Connections\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Individual supply and return connection for each PEX loop\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Circulator\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Integrated hydronic circulator pump\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n      \u003c!-- RIGHT TABLE --\u003e\n\n      \u003cdiv class=\"ws-electric-panel-spec-table\"\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Expansion Control\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Panel-mounted expansion tank\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Air Management\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Integrated air-separation components\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            System Controls\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Panel-mounted thermostat and circulation controls\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Loop Control\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Individual manifold flow adjustment and balancing\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Installation Format\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Wall-mounted mechanical panel assembly\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Field Connections\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Electrical service, thermostat, system water and PEX loops\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"ws-electric-panel-spec-row\"\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-label\"\u003e\n            Assembly\n          \u003c\/div\u003e\n          \u003cdiv class=\"ws-electric-panel-spec-value\"\u003e\n            Professionally assembled and supported in the USA\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n  \u003c!-- SYSTEM SIZING AND INSTALLATION --\u003e\n\n  \u003csection class=\"ws-electric-panel-section\"\u003e\n\n    \u003cdiv class=\"ws-electric-panel-notice\"\u003e\n\n      \u003ch3\u003eSystem Sizing and Installation\u003c\/h3\u003e\n\n      \u003cp\u003e\n        Radiant heating system selection should be based on a professional\n        heat-loss calculation, required water temperature, PEX loop lengths,\n        building insulation, local climate and available electrical service.\n        Square footage alone is not sufficient for accurately sizing the\n        heating system.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        The electric boiler requires a properly sized dedicated electrical\n        circuit. Breaker size, conductor size and final electrical\n        requirements must be confirmed for the boiler supplied with the panel.\n      \u003c\/p\u003e\n\n      \u003cp\u003e\n        Final electrical work, thermostat wiring, system piping, PEX\n        connections, filling, purging, startup and commissioning should be\n        completed by qualified professionals in accordance with the equipment\n        instructions and applicable codes.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"Warming Systems Hydronic","offers":[{"title":"2-Loop","offer_id":53790918934712,"sku":null,"price":2700.0,"currency_code":"USD","in_stock":true},{"title":"3-Loop","offer_id":53790918967480,"sku":null,"price":2750.0,"currency_code":"USD","in_stock":true},{"title":"4-Loop","offer_id":53790919000248,"sku":null,"price":2800.0,"currency_code":"USD","in_stock":true},{"title":"5-Loop","offer_id":53790919033016,"sku":null,"price":2850.0,"currency_code":"USD","in_stock":true},{"title":"6-Loop","offer_id":53790919065784,"sku":null,"price":2900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/2376\/8760\/files\/2-Loop-Front-Zone_Control_Manifold_Pump_Tank_7c8cb89b-e1db-4ea8-8474-d2b167189e97.png?v=1784571160"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/2376\/8760\/collections\/2-Loop-Front-Zone_Control_Manifold_Pump_Tank_7c8cb89b-e1db-4ea8-8474-d2b167189e97.png?v=1784571644","url":"https:\/\/warmingsystemshydronic.com\/collections\/electric-boiler-panels.oembed","provider":"Warming Systems Hydronic","version":"1.0","type":"link"}